WARN Reliability AgentAI-3374
Bad actor — Pump P-402 failed 3 times in 6 months
P-402 · Terminal East
Confidence
79%
ImpactRepair spend $28K · availability −1.4%
Probable causes
- Seal flush plan inadequate for service
- Repeated dry-run events on start-up
- Misalignment recorded twice
Recommended actions
- Open RCA with reliability engineer
- Revise API plan 11 to plan 32
- Add start-up interlock
- Laser alignment on next PM
Data analysed
- 3 work orders
- Technician notes
- Operating condition history
- Spare parts consumption
Governance: human approval required for safety-critical execution